The unit will operate on 220V, 50 Hz Single Phase OR 380 -
440V - 480V AC, +/- 10 %, 50 or 60 Hz, +/- 5 Hz with an isolation transformer
that will supply power to all electronic panels and will have fire proof and
single-phase circuit breakers (MCB’s) for
protection. |
Each equipment will have a separate AC socket and additionally eight extra
sockets are provided with 15A circuit breaker.
All
instruments including computers and peripherals operate on 220V +/- 20 %, 50Hz or +/- 5 Hz.
The
instrumentation racks are powered through a CVT and UPS provided with over
voltage and filter circuits to take care of supply variations in the Rig
supply.
|
|
Two
bundles of Power Cable of 100-meter length with earthing
facility for carrying rig supply to the Mud logging Unit. The cables are of
standard reputed make with fire and flameproof capabilities conforming to VDE
0295 Class 5 specifications. |
All
Sensors have sufficient cable of 300 feet each. The cables are copper multicore with FRPVC or EPR sheathing with a copper braided
shielding.
All
instruments are mounted on shock proof modular Instrumentation Rack.
|
|
All
Electrical Wiring and fixtures, breakers, relays, plugs, etc confirm to
industrial safety regulations and standards. |
An
Isolation Transformer will be provided as an option inside the unit for
deriving 220V AC, 50 Hz or 60 Hz and 440 V AC, 50 or 60 Hz Hz
with a delta input and star output. Neutral
is generated from the transformer.
Input to transformer will be 380V –440 – 480 V, +/- 10 % with
tapping provided.