Cabin Specifications

 

Dimensions

: -

20’ x 8.0’ x 8.0’ (L x W x H)

Operating Temp.

: -

0 - 55 deg C

Relative Humidity

: -

95% RH Non- condensing

Power requirements

: -

220V, 50 Hz OR 380V - 440V - 480V - 3 phase, 50 or 60 Hz

Intrinsically Safe Electrical System

Frequency

: -

50 or 60 Hz.   +  5 Hz.

Weight

: -

8 to 10 tons

Air conditioning

: -

Two 1.5/2.0 Ton A/C’s to maintain Ambient Temp. 220C fitted with De-humidifiers

Pressurization

: -

Positive Pressure with Automatic Power Shut Off

UPS

: -

2x 2 KVA with 60 minutes backup of sufficient rating to run unit & associated equipment

Safety   Features

: -

Interior Combustible gas alarm

Interior emergency lighting system.  Escape Hatch

Self supporting steel construction

Inside walls covered with laminated hard board, insulated with high density fire resistant and dust repelling rock wool against extreme external temperatures.  Having a good aesthetic sense conforming to ISI Floor covered with acid proof PVC, Side walls made of G.I sheet, 2mm thick corrugated with interior laminates with moth proof coating and vinyl flooring.

 

 

 

 

 

 

 

 

 

·         The unit is provided with a Wet Section with a provision of Hot and Cold water and complete drainage facility. Sample washing, drying, examination, storage is done in this area.

·         Four Fireproof blankets are kept in the units.

·         The cabin is skid mounted, provided with four lifting eyes for loading and mobilization.

·         The body of the cabin is insulated, sturdy, corrosion proof, leak proof, and contains cabinets, drawers, 2 stools, two revolving chairs, folding type cushioned seats, writing desks, tracing table and book shelves, with windows and anti - panic escape door.

 

·         The unit is positively pressurized with pressure indicators, alarms, a purge mechanism, suitable audio alarm, sufficient length of flexible and flameproof fresh air hose and positive double lockout doors with an intrinsically safe explosion proof system and automatic shutdown system for use in Zone 1 hazardous environments. Excess pressure inside the cabin will be 5mm to 10mm of water column above atmospheric pressure.

·         The unit is equipped with a washbasin and tap, sanitary items and chemical box.

·         The unit has storage space for all types of consumables for one month, spare parts of the panels and administrative records of the well and the unit.

·         The unit has a switch fuse unit and ELCB, MPB, MCB for protection.

·         Two portable Fire Extinguishers of Class A, B and C of suitable size are provided.