Page 5 of 18

 

 

Drill-Data System  DDS

The following parameters are monitored on the Drill Data System: -

 

1.      Drilling RATE – ROP and Drilled Depth

2.    Stand pipe Pressure - SPP

3.    Casing Pipe Pressure - CPP

4.    Torque (Rotary)

5.     RPM    (Rotary)

6.    Hook Load/WOB

7.     SPM

 

The detailed specifications are listed below: -

 

1.              Drilling Rate (In mts/hr and mins/mtr)

and Drilled Depth with Kelly Position

Accuracy

:

+  0.1% of full scale

Range

:

0 - 8000mts.

Recording Interval          

:

0.25mts., 0.5, 1.0mts.

Sensor

:

Ex-Proof Proximity Sensor or Rotary Encoder Three independent encoder type sensors suitable for mounting on Draworks drum, Crown Block and Geolograph are provided.

 

·                     Block Height and block speed are also monitored.

·                     Three sensors are provided to minimize down time of ROP system and any one of the sensors can be used for sensing ROP. Change over is done in software within seconds.

·                     Parameters recorded and displayed are ROP in min./ meter, Meters /hr, feet/hr., Instantaneous ROP, Average ROP.

·                     Programmable Drill Break Alarm

 

Rotary Encoder

Heave Sensor and Heave compensation as applicable are provided for offshore operation.

 

 

 

 

2.    Stand Pipe Pressure              (SPP)

 

Sensor         

:

Piezo resistive  / capacitance.

Mounting

:

Standpipe Manifold

Accuracy

:

+ 0.075%

Sensitivity

:

0.5 psi

Response

:

100ms

Stability

:

3.5 psi for 5 years

Range

:

0 – 10,000 psi. or  700 kgs/cm2

Linearity

:

0.5 % 

Approvals

:

Ex-Proof Certified for

 Class I. Factory Sealed.

Outputs

:

Recorder, Monitor, Printer

 

 

 

 

 


 

3.   Torque (Rotary)

 

Sensor

:

Electrical (Hall effect)

Mounting

:

On Draw-works or Top Drive cable

Accuracy

:

+  1%

Sensitivity

:

1 Amp

Range

:

0 – 1000 Amps or Klbs.

Approvals

:

Intrinsically Safe suitable for Class I

Outputs

:

Recorder, Monitor, Printer