Page 6 of 18 |
4.
Draw work RPM
|
Sensor |
: |
Inductive Proximity Switch |
|
|
Mounting |
: |
On Rotary Table |
|
|
Accuracy |
: |
+ 1 RPM |
|
|
Range |
: |
0 - 200 RPM |
|
|
Sensing
Distance |
: |
30 mm |
|
|
Approvals
|
: |
|
5.
Weight on Bit and Hook load
|
Sensor |
: |
Piezo
resistive / capacitance. |
|
|
Mounting |
: |
Dead Line Anchor |
|
|
Accuracy |
: |
+0.2% |
|
|
Sensitivity |
: |
0.16psi |
|
|
Response |
: |
200ms |
|
|
Stability |
: |
+/- 0.8 psi
per year |
|
|
Range |
: |
0 – 1000 psi. |
|
|
Linearity |
: |
0.5 % |
|
|
Approvals |
: |
Ex-Proof Certified for |
|
|
Outputs |
: |
Recorder, Monitor, Printer |
5.
Pump strokes
|
Sensor |
: |
Inductive Proximity Switch |
|
|
Mounting
|
: |
On Mud Pumps |
|
|
Accuracy |
: |
+ 1 RPM |
|
|
Range |
: |
0 - 200 RPM |
|
|
Sensing
Distance |
: |
30 mm |
|
|
Approvals
|
: |
|
|
|
Provision is provided
for operation of four pumps at a time. |
|||
7. Casing
Pipe Pressure (CPP)
|
Sensor |
: |
Piezo resistive /
capacitance. |
|
|
Mounting |
: |
Choke Manifold |
|
|
Accuracy |
: |
+ 0.075% |
|
|
Sensitivity |
: |
0.5 psi |
|
|
Response |
: |
100ms |
|
|
Stability |
: |
3.5 psi for 5 years |
|
|
Range |
: |
0 – 10,000 psi. or 700 kgs/cm2 |
|
|
Linearity |
: |
0.5 % |
|
|
Approvals |
: |
Ex-Proof Certified for |
|
|
Outputs |
: |
Recorder, Monitor, Printer |