Page 8 of 18 |
4.Mud Flow rate IN/OUT with SPM
|
Mud flow rate IN : |
|
|
|
|
Flow Rate In Sensor |
: |
Electrical
switch or Proximity Sensor Flow In calculated from SPM. |
|
|
Flow out |
: |
Direct reading system |
|
|
Flow Rate out Sensor |
: |
Paddle type or Ultrasonic |
|
|
Accuracy |
: |
+/- 1 % |
|
|
Range |
: |
0 to 4000 liters /minute |
4.
Mud Volume Totalizer with
Individual Tank Indicator
|
|
Sensor |
: |
Ultrasonic Sensor |
|
Accuracy |
: |
+ 0.2 cubic meters in
100m3 |
|
|
Range |
: |
0 to 100 cubic meter pit |
|
|
No. of Tanks |
: |
Up to 10 tanks |
|
|
Height of tanks |
: |
Up to 5 meters |
|
|
Indication |
: |
One for each pit with
local indication and summation of all readings displayed on central monitor |
6. Trip Tank
Sensor : Ultrasonic Sensors
Accuracy : +
0.2 cubic meters
Alarms
are set for High and Low values on each parameter
|
|
All
field mounted sensors are intrinsically safe mounted in explosion proof
junction boxes meeting safety standards of Area ‘0’ hazardous as per API,
powered through Certified zener barriers in the
bunk house and compatible for different types of rigs. All sensor cables are
certified for use in zone zero areas. |
Junction
Boxes: All Sensor unction boxes are Certified Intrinsically
Safe or Explosion Proof, certified for use in
Class I areas.