4.Mud Flow rate    IN/OUT with SPM

 

Mud flow rate IN :

 

 

 

 

 

Flow Rate In Sensor

:

Electrical switch or Proximity Sensor

Flow In calculated from SPM.

Flow out

:

Direct reading system

Flow Rate out Sensor

:

Paddle type or Ultrasonic

Accuracy

:

+/- 1 %

Range

:

0 to 4000 liters /minute

 

 

 

 

 

 

 

 

 

4.   Mud Volume Totalizer with Individual Tank Indicator

 

 

Sensor

:

Ultrasonic Sensor

Accuracy

:

+ 0.2 cubic meters in 100m3

Range

:

0 to 100 cubic meter pit

No. of Tanks

:

 Up to 10 tanks

Height of tanks

:

 Up to 5 meters

Indication

:

One for each pit with local indication and summation of all readings displayed on central monitor

 

6. Trip Tank 

        Sensor                              :        Ultrasonic Sensors 

     Accuracy                          :        + 0.2 cubic meters

     Range                               :        0 to 100 Cu .Meters

     Tank size                         :           2.5 meters x 2.0 meters.  

 

Alarms are set for High and Low values on each parameter 

 

 

All field mounted sensors are intrinsically safe mounted in explosion proof junction boxes meeting safety standards of Area ‘0’ hazardous as per API, powered through Certified zener barriers in the bunk house and compatible for different types of rigs. All sensor cables are certified for use in zone zero areas.

 

Junction Boxes: All Sensor unction boxes are Certified Intrinsically Safe or Explosion Proof, certified for use in   Class I areas.